Sign In | Join Free | My chinaqualitycrafts.com
China SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD logo
SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
Verified Supplier

5 Years

Home > Low Voltage Power Cable >

Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable

SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable

  • 1
  • 2

Brand Name : DONGJIAXIN

Model Number : YJV

Certification : QS

Place of Origin : CHINA

MOQ : Negotiable

Price : Negotiable

Payment Terms : L/C, T/T

Supply Ability : 100KM/Week

Delivery Time : 7-15 working days

Packaging Details : Steel wooden drum

Model Name : YJV

Rated Voltage : 0.6/1KV

Size : 1.5~630mm²

Nos. of Core : 2~5

Conductor Type : stranded annealed copper Class 2

Sheath : PVC

Fire Performance : IEC 60332-1

Application : Construction, underground,Power Engineering, Rail Transit

Contact Now

Copper Conductor XLPE Insulation and PVC Jacket Power Cable

Application:

1kV for Fixed installations such as distribution networks or industrial installations.

Construction:

Core Conductor annealed copper (stranded core)
Popular sizes 2~5core x1.5~630mm²
Cable conductor stranded annealed copper
Insulation XLPE
Jacket PVC
Temperature rating -25C up to +90℃
Voltage suitable 0.6/1kV
Fire performance IEC 60332-1
Approval QS in China

Advantage:

It has excellent thermal-mechanical properties, excellent electrical properties and chemical corrosion resistance, and also has the advantages of simple structure, light weight, and no drop limit for laying.

Standards&Certificates:

IEC 60502-1

▼ Technical parameters:

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.7 1.4 5.2 12.1
1×2.5 1 0.7 1.4 5.6 7.41
1×4 1 0.7 1.4 6.0 4.61
1×6 1 0.7 1.4 6.5 3.08
1×10 7 0.7 1.4 7.6 1.83
1×16 7 0.7 1.4 8.6 1.15
1×25 7 0.9 1.4 10.2 0.727
1×35 7 0.9 1.4 11.2 0.524
1×50 10 1.0 1.4 12.5 0.387
1×70 14 1.1 1.4 14.3 0.268
1×95 19 1.1 1.5 16.5 0.193
1×120 24 1.2 1.5 18.2 0.153
1×150 30 1.4 1.6 20.1 0.124
1×185 37 1.6 1.6 22.2 0.0991
1×240 48 1.7 1.7 24.9 0.0754
1×300 61 1.8 1.8 27.5 0.0601
1×400 61 2.0 1.9 30.8 0.0470
1×500 61 2.2 2.0 34.3 0.0366
1×630 61 2.4 2.2 41.3 0.0283

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 0.7 1.8 8.9 12.1
2×2.5 1 0.7 1.8 9.7 7.41
2×4 1 0.7 1.8 10.6 4.61
2×6 1 0.7 1.8 11.6 3.08
2×10 7 0.7 1.8 13.8 1.83
2×16 7 0.7 1.8 15.7 1.15
2×25 7 0.9 1.8 18.9 0.727
2×35 7 0.9 1.8 20.9 0.524
2×50 10 1.0 1.8 24.6 0.387
2×70 14 1.1 1.8 28.2 0.268
2×95 19 1.1 1.9 32.4 0.193
2×120 24 1.2 2.0 35.8 0.153
2×150 30 1.4 2.2 39.6 0.124
2×185 37 1.6 2.3 44.0 0.0991
2×240 48 1.7 2.5 49.4 0.0754
2×300 61 1.8 2.6 54.3 0.0601
2×400 61 2.0 2.9 61.0 0.0470
2×500 61 2.2 3.1 68.4 0.0366
2×630 61 2.4 3.3 82.0 0.0283
3×1.5 1 0.7 1.8 9.4 12.1
3×2.5 1 0.7 1.8 10.2 7.41
3×4 1 0.7 1.8 11.2 4.61
3×6 1 0.7 1.8 12.2 3.08
3×10 7 0.7 1.8 14.6 1.83
3×16 7 0.7 1.8 16.7 1.15
3×25 7 0.9 1.8 20.1 0.727
3×35 7 0.9 1.8 22.3 0.524
3×50 10 1.0 1.8 26.2 0.387
3×70 14 1.1 1.9 30.3 0.268
3×95 19 1.1 2.0 34.6 0.193
3×120 24 1.2 2.1 38.5 0.153
3×150 30 1.4 2.3 42.6 0.124
3×185 37 1.6 2.4 47.3 0.0991
3×240 48 1.7 2.6 53.1 0.0754
3×300 61 1.8 2.7 58.2 0.0601
3×400 61 2.0 3.0 65.6 0.0470
3×500 61 2.2 3.2 73.5 0.0366
3×630 61 2.4 3.5 88.2 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 1.8 10.1 12.1
4×2.5 1 0.7 1.8 11.0 7.41
4×4 1 0.7 1.8 12.1 4.61
4×6 1 0.7 1.8 13.3 3.08
4×10 7 0.7 1.8 16.0 1.83
4×16 7 0.7 1.8 18.3 1.15
4×25 7 0.9 1.8 22.1 0.727
4×35 7 0.9 1.8 24.6 0.524
4×50 10 1.0 1.8 28.8 0.387
4×70 14 1.1 2.0 33.4 0.268
4×95 19 1.1 2.1 38.4 0.193
4×120 24 1.2 2.3 43.0 0.153
4×150 30 1.4 2.4 47.3 0.124
4×185 37 1.6 2.6 52.7 0.0991
4×240 48 1.7 2.8 59.0 0.0754
4×300 61 1.8 3.0 65.1 0.0601
4×400 61 2.0 3.3 73.3 0.0470
4×500 61 2.2 3.5 82.0 0.0366
4×630 61 2.4 3.8 98.6 0.0283
5×1.5 1 0.7 1.8 10.9 12.1
5×2.5 1 0.7 1.8 11.9 7.41
5×4 1 0.7 1.8 13.1 4.61
5×6 1 0.7 1.8 14.5 3.08
5×10 7 0.7 1.8 17.4 1.83
5×16 7 0.7 1.8 20.0 1.15
5×25 7 0.9 1.8 24.3 0.727
5×35 7 0.9 1.8 27.0 0.524
5×50 10 1.0 1.9 31.9 0.387
5×70 14 1.1 2.1 36.9 0.268
5×95 19 1.1 2.2 42.5 0.193
5×120 24 1.2 2.4 47.5 0.153
5×150 30 1.4 2.6 52.5 0.124
5×185 37 1.6 2.8 58.4 0.0991
5×240 48 1.7 3.0 65.5 0.0754
5×300 61 1.8 3.2 72.3 0.0601
5×400 61 2.0 3.5 81.2 0.0470
5×500 61 2.2 3.8 91.2 0.0366
5×630 61 2.4 4.1 109.5 0.0283

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 0.7 1.8 10.8 7.41
3×4+1×2.5 1 0.7 1.8 11.8 4.61
3×6+1×4 1 0.7 1.8 13.0 3.08
3×10+1×6 7 0.7 1.8 15.3 1.83
3×16+1×10 7 0.7 1.8 17.7 1.15
3×25+1×16 7 0.9 1.8 21.2 0.727
3×35+1×16 7 0.9 1.8 23.0 0.524
3×50+1×25 10 1.0 1.8 27.4 0.387
3×70+1×35 14 1.1 1.9 31.5 0.268
3×95+1×50 19 1.1 2.1 36.1 0.193
3×120+1×70 24 1.2 2.2 40.5 0.153
3×150+1×70 30 1.4 2.3 43.8 0.124
3×185+1×95 37 1.6 2.5 49.2 0.0991
3×240+1×120 48 1.7 2.6 55.0 0.0754
3×300+1×150 61 1.8 2.8 60.5 0.0601
3×400+1×185 61 2.0 3.1 68.1 0.0470
3×500+1×240 61 2.2 3.3 76.3 0.0366
3×630+1×300 61 2.4 3.6 90.1 0.0283
3×2.5+2×1.5 1 0.7 1.8 11.5 7.41
3×4+2×2.5 1 0.7 1.8 12.6 4.61
3×6+2×4 1 0.7 1.8 13.9 3.08
3×10+2×6 7 0.7 1.8 16.2 1.83
3×16+2×10 7 0.7 1.8 19.0 1.15
3×25+2×16 7 0.9 1.8 22.6 0.727
3×35+2×16 7 0.9 1.8 24.2 0.524
3×50+2×25 10 1.0 1.8 29.1 0.387
3×70+2×35 14 1.1 2.0 33.3 0.268
3×95+2×50 19 1.1 2.1 38.2 0.193
3×120+2×70 24 1.2 2.3 43.3 0.153
3×150+2×70 30 1.4 2.4 46.3 0.124
3×185+2×95 37 1.6 2.5 52.0 0.0991
3×240+2×120 48 1.7 2.7 58.1 0.0754
3×300+2×150 61 1.8 2.9 64.2 0.0601
3×400+2×185 61 2.0 3.2 72.1 0.0470
3×500+2×240 61 2.2 3.5 80.9 0.0366
3×630+2×300 61 2.4 3.8 94.7 0.0283

5. 4+1 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×2.5+1×1.5 1 0.7 1.8 11.7 7.41
4×4+1×2.5 1 0.7 1.8 12.9 4.61
4×6+1×4 1 0.7 1.8 14.2 3.08
4×10+1×6 7 0.7 1.8 16.8 1.83
4×16+1×10 7 0.7 1.8 19.5 1.15
4×25+1×16 7 0.9 1.8 23.4 0.727
4×35+1×16 7 0.9 1.8 25.6 0.524
4×50+1×25 10 1.0 1.9 30.6 0.387
4×70+1×35 14 1.1 2.0 35.0 0.268
4×95+1×50 19 1.1 2.2 40.5 0.193
4×120+1×70 24 1.2 2.3 45.3 0.153
4×150+1×70 30 1.4 2.5 49.4 0.124
4×185+1×95 37 1.6 2.6 55.2 0.0991
4×240+1×120 48 1.7 2.9 61.9 0.0754
4×300+1×150 61 1.8 3.1 68.3 0.0601
4×400+1×185 61 2.0 3.4 76.7 0.0470
4×500+1×240 61 2.2 3.6 86.0 0.0366
4×630+1×300 61 2.4 3.9 102.1 0.0283

Company information:

30 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

Annual revenue is about 500 million US dollars.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable

Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable

FAQ

* How to assure the quality of products?

1. Most of our products have certification.

2. Our Lab staff will test the material and check the process card before production.

3. The O.D tester is testing all the time during production, and the production line is always under control.

4. The product will be tested by Lab staff after production.

* Do you offer free samples or not?

1. If we have inventory about the sample you need and the total amount is not large, it's free.

2. If we don't have inventory, according to our company's rule, sample and freight costs need to be paid by your esteemed company. And we will return the sample cost to you when you place the first order with us. Thanks for your support.

* When I want customized products, how to do it?

We have professional equipment, technicians & skilled employees, OEM & customized service is welcome. Drawings or samples are required. Of course, the purchased quantity should meet our MOQ.


Product Tags:

YJV pvc insulated power cable

      

1.5 sqmm pvc insulated power cable

      

pvc 3 core 1.5 sq mm power cable

      
Quality Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable for sale

Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)